HostVenom & WinterNode - Historial de avisos

Sistemas funcionando con normalidad

Historial de avisos

feb 2026

Degraded Service Performance - Miami Data Center
  • Resuelto
    UTC
    Resuelto

    The network connectivity issue has been identified as a DDoS attack, which has now been successfully mitigated. Network performance and all related services have returned to normal operation.

    During the investigation, a cooling issue affecting gs103.mia.winternode.com was also identified. This matter is unrelated to the DDoS event. We will coordinate with the data center team to schedule a separate maintenance window to address the cooling concern.

    Customers are encouraged to subscribe to our status page and follow the gs103.mia component for updates regarding the upcoming maintenance schedule and completion details.

  • Actualizar
    UTC
    Actualizar

    We have received a response from our service provider. Based on their initial investigation, they believe the issue is related to cooling and have escalated the matter to the Data Center Team for further inspection and any necessary corrective action.

    We have requested additional details to better understand the situation. From our observations, the behavior appears to be network related, as none of the game servers were forcefully powered off as this incident is ongoing.

    We will continue to share more information as it comes available.

  • Investigando
    UTC
    Investigando

    Our automated monitoring has detected an issue affecting game servers at our Miami data center. We have ticketed our service provider for more information.

    More details will be shared as they become available.

Chicago DC - Network Issue
  • Resuelto
    UTC
    Resuelto

    An upstream routing misconfiguration was identified and has been resolved. All affected services are fully operational and stable.

    This incident is now considered resolved. If you experience any further issues, please contact our support team at https://winternode.com/support .

  • Supervisando
    UTC
    Supervisando

    Our uptime monitors are now reporting all affected services as online again. This appears to have only been a network outage and no machines were restarted.

    We will continue to monitor and work with the data center to determine the reason for this outage.

    If you are still experiencing issues, please reach out to our support team via https://winternode.com/support .

  • Investigando
    UTC
    Investigando

    Our automated monitoring has detected a problem related to WinterNode.com & HostVenom.com services at our Chicago Data Center and are actively investigating.

    More details to follow.

ene 2026

gs101.lax Hardware Issue
  • Resuelto
    UTC
    Resuelto

    The node is back online and accessible. Our provider completed hardware diagnostics and replaced the power supply unit. Customers can now start their servers back online. We are actively monitoring the node for stability and will open a new incident if further action is needed.

  • Actualizar
    UTC
    Actualizar

    gs101.lax will be powered off within the next few minutes to allow the emergency hardware check to begin. We will power off all game servers to ensure data integrity. This comprehensive test will ran overnight.

    Please subscribe to this incident to receive further updates - https://status.hostvenom.com/cmkyfkdm40cf5vqph57soirg5 .

  • Identificado
    UTC
    Identificado

    We're are scheduling EMERGENCY HARDWARE MAINTENANCE for gs101.lax to start at 2AM Eastern Time US on January 29th, 2026.

    A comprehensive hardware test will be conducted by our service provider during this time period to ensure this machine is stable for future activities. We expect this to take 4 hours to 6 hours.

  • Investigando
    UTC
    Investigando

    Our service provider has picked up our ticket and is actively working to diagnosis this issue.

    Game servers will not be accessible during this time. We will keep you updated on when customers will be able to start their services again.

  • Supervisando
    UTC
    Supervisando

    We have reviewed the server console and have forwarded a copy of the displayed logs to our service provider.

    We have rebooted the node to allow customers to access their game servers and will await the response from the data center team.

  • Investigando
    UTC
    Investigando

    An automated alert has been triggered by our monitoring system and our team has been notified. We are currently investigating this incident.

`gs101.lax` network unreachable
  • Resuelto
    UTC
    Resuelto

    No immediate issues were noticed from the test conducted. We have restarted the machine and have confirmed services are online again.

    If you are still experiencing issues, please reach out to our support team - https://winternode.com/support .

  • Identificado
    UTC
    Identificado

    Management team members are actively investigating this incident, which appears to be a Kernal Panic from first glance. We will run a few tests to ensure hardware stability before releasing this back to customers.

  • Investigando
    UTC
    Investigando

    An automated alert has been triggered by our monitoring system and our team has been notified. We are currently investigating this incident.

dic 2025

Network Connectivity Issues with MC.LON5
  • Resuelto
    UTC
    Resuelto

    This incident has been resolved. We will create a new incident if necessary, however, changes have been made to better protect our Node IP.

    Please reach out over Discord or Client Area Tickets if you are experiencing any issues.

  • Actualizar
    UTC
    Actualizar

    We observed some servers were still having connectivity issues on mc.lon5 and have applied an additional fix.

    If you need any assistance with your server please reach out to our support team.

    We are continuing to monitor, but as this update everything should be online and functional.

  • Actualizar
    UTC
    Actualizar

    We saw another attack that impacted this box, and we have made an adjustment in discussion with our upstream provider. Panel server management should be restored again.
    We are continuing to monitor this node.

    If you would like to move to another node (at our other provider) to avoid this issue, we're happy to transfer you. Please open a ticket.

  • Supervisando
    UTC
    Supervisando

    One of our IP addresses was temporarily unavailable due to a large external DDoS attack. Service has since been restored, and we are actively monitoring the situation to determine whether further action is needed.

    We are in contact with the provider and monitoring the situation. They have shared some options if attacks continue.

  • Identificado
    UTC
    Identificado

    Our service provider has booted our machine into rescue mode and the technician that looked into it was unable to resolve the issue. They have returned our machine back into the normal operating system without networking still.

    Our ticket has now been assigned to the network team with our service provider, although we might be waiting longer than normal for a reply as it is a specific team.

  • Investigando
    UTC
    Investigando

    We have rebooted the node at the suggestion of the service provider. This has not resolved the network issue. We have provided more information to the service provider to see if this is a configuration issue on their end.

  • Identificado
    UTC
    Identificado

    Our automated alerts have been triggered again and we are receiving support tickets regarding services on MC.LON5 being inaccessible.

    We have reviewed the server console and gameservers are still running, however, logging onto the server may be affected. We have re-opened our ticket with our service provider for more details and will post updates as they come in.

  • Resuelto
    UTC
    Resuelto

    We've received an update from our upstream provider. Similar to the November Chicago Data Center incident, they reported high-volume "carpet bomb" DDoS activity that temporarily placed a large number of IPs into mitigation.

    We have not received any customer reports of disconnections. The provider advised that only ICMP (ping) may have been filtered during mitigation, which can trigger false positives on our uptime monitors. Regular TCP and UDP traffic was not impacted, and our IP addresses have now been removed from mitigation.

  • Investigando
    UTC
    Investigando

    We have received a few automated alerts regarding network connectivity issues to MC.LON5. We have confirmed with additional MTR tests that some clients might be unable to join servers hosted on MC.LON5.

    A ticket has been filed and we are awaiting further information from our service provider.

`gs101.lax` Unavailable [Machine]
  • Resuelto
    UTC
    Resuelto

    This incident has been resolved and all customers we have checked in with are reporting they are able to connect and manage their service.

  • Supervisando
    UTC
    Supervisando

    We have restarted the network interface and confirmed that the IPs serving our game server customers are properly bound to the node. After starting multiple game servers, we can confirm that they are now coming online successfully.

    We ask all customers to start their servers and report any issues. We are moving this incident to the monitoring status and will be marked as resolved in one hour if no further problems are observed.

  • Actualizar
    UTC
    Actualizar

    A member of our management team has reviewed the server console and confirmed that the machine experienced a kernel panic. The server has been hard reset and has successfully rebooted to the operating system login screen.

    After attempting to start a game server, customers may encounter an error similar to:

    (HTTP code 500) server error - failed to set up container networking: driver failed programming external connectivity on endpoint ... (...): failed to bind host port for .../tcp: cannot assign requested address

    We are actively investigating this issue.

  • Investigando
    UTC
    Investigando

    An automated alert has been triggered by our monitoring system and our team has been notified. We are currently investigating this incident.

    The node has not responded after a restart. This has been escalated to the team to take a look at.

dic 2025 a feb 2026

Siguiente